Migration Entry/Entry Fields


Global Fields

Migration Date
When entered, this establishes a date for the migration request. Once the migration request is approved, it will not be acted upon until the specified migration date is reached. If this field is left blank, it will default to the current date, and will be acted upon as soon as it is approved.

Request #
This field is used when editing a previously entered request. If a migration request number that is pending migration is entered, that request (if it exists) will be displayed for updating. If a new migration request is entered, once updating has taken place, a number will be assigned to the request and will be displayed in this field. If an existing request is entered, automatic preceding zero-padding will take place.

Reference Number
This is a 6 character free-form field that can be used as needed. Normally, when used, it will contain the associated Request Tracking reference number.

Request Fields

Each request permits a maximum of 12 members to be specified. Each member has additional fields associated with the member, some of which may be optionally entered. Use the help screen associated with the migration entry panel for valid values.

Language
This field represents the language associated with the member to be migrated. Valid values are contained on the BML table. This field is informational only, and is automatically selected based on the language type of the member in the specified Panvalet library.

Load Proc
This field is the load proc associated with the member. It is valid only for Cobol and Assembly (ASMB) programs. For a list of valid load procs, see the BMP table. If an SCT proc is specified, the MGC table is used to assure and/or substitute the correct proc.

SCT System
This field is the SCT system the member represents. This is only valid when an SCT load proc is specified. Only the first letter of the system needs to be specified. Valid values are on the MGS table. This field is automatically determined by the MGC table.

Status
This field is predetermined by the originating library and is displayed for informational purposes only. If the originating library is PCP40, PCP41 or PCP42, the member is to be deleted. Any other library will have a status of enabled.

Documentation Changes
This field is valid only for JCL members. It indicates if revised documentation exists for this job. Documentation changes must be in place before entering the migration request. The test documentation files are queried and this field is determined based on the results of that query. It is informational only.

Special Option
This field is used for special processing options. Valid values are on the MGO table, and includes, for example, JCL Procs. JCL Procs must have a language type of OTHER.

©2004 All Rights Reserved